Percolation tests explained
A percolation test measures how fast water soaks into your soil. It decides whether a drainage field can work and how big it needs to be.
How the test is done
Approved Document H sets out the method:
- Dig a trial hole at least 2m deep (or 1.5m below the planned pipes) to check the water table.
- Dig a 300mm square test hole, 300mm below where the pipes will go.
- Fill it with water to at least 300mm and let it soak away overnight.
- Next day, refill it and time how long the water takes to drop from 75% to 25% full (150mm).
- Divide the time in seconds by 150. That is the Vp, seconds per millimetre.
- Repeat at least three times in at least two holes, and take the average.
Don't test in heavy rain, frost or drought.
What the result means
- Vp between 12 and 100: a drainage field can work.
- Below 12: water drains too fast to clean the effluent properly.
- Above 100: the ground drains too slowly, common in heavy clay.
The winter water table must also stay at least 1m below the pipes. If the ground fails, a treatment plant to a flowing watercourse may be the answer.
Checked against GOV.UK guidance: 24 November 2026. Rules apply to England.